Evaluation of Delivery Analysis to Detect Intrafractional Motion during Tomotherapy
Abstract: The purpose of this study was to investigate the ability of a management system (Delivery Analysis: DA) to detect intrafractional motion during intensity-modulated radiation therapy (IMRT) in tomotherapy mode. Tomotherapy has made it possible to manage internal movements during treatment using software DA, which quantifies using the information of the passing dose obtained during the radiation treatment of patients. First, three treatment plans for the test were created (lumbar spine, prostate, and femur). Second, a pelvis phantom was moved in the X, Y, and Z directions, and a sinogram was acquired. The magnitudes of the movements were 3 mm, 5 mm, and 10 mm, respectively. Finally, the ability of DA to detect the motion was evaluated by comparing the sinogram obtained by moving the phantom with a reference sinogram obtained without movement. The sensitivity of DA could be detected with a shift amount of 3 mm (gamma analysis tolerance 0.3 mm/0.3%). The average gamma analysis of each direction at 0.3 mm/0.3% tolerance at each treatment site was 96.1% for the prostate, 93.5% for the lumbar spine, and 94.4% for the femur. Additionally, the average gamma pass rate results for the pelvic phantom in the X, Y, Z directions for a 10 mm shift were 96.2%, 96.3%, and 95.9%, respectively. DA is a powerful tool with high detection sensitivity and ability to detect body movement during treatment.
Cite this paper: Tarutani, K. , Tanooka, M. , Sano, K. , Wataru, O. , Fujiwara, M. and Yamakado, K. (2019) Evaluation of Delivery Analysis to Detect Intrafractional Motion during Tomotherapy. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 8, 225-235. doi: 10.4236/ijmpcero.2019.84020.
References

[1]   Staffurth, J. (2010) Radiotherapy Development Board. A Review of the Clinical Evidence for Intensity-Modulated Radiotherapy. Clinical Oncology, 22, 643-657.
https://doi.org/10.1016/j.clon.2010.06.013

[2]   Viani, G.A., Viana, B.S., Martin, J.E., Rossi, B.T., Zuliani, G. and Stefano, E.J. (2016) Intensity-Modulated Radiotherapy Reduces Toxicity with Similar Biochemical Control Compared with 3-Dimensional Conformal Radiotherapy for Prostate Cancer: A Randomized Clinical Trial. Cancer, 122, 2004-2011.
https://doi.org/10.1002/cncr.29983

[3]   Mackie, T.R., Holmes, T., Swerdloff, S., et al. (1993) Tomotherapy: A New Concept for the Delivery of Dynamic Conformal Radiotherapy. Medical Physics, 20, 1709-1719.
https://doi.org/10.1118/1.596958

[4]   Feygelman, V., Opp, D., Javedan, K., Saini, A.J. and Zhang, G. (2010) Evaluation of a 3D Diode Array Dosimeter for Helical Tomotherapy Delivery QA. Medical Dosimetry, 35, 324-329.
https://doi.org/10.1016/j.meddos.2009.10.007

[5]   Myers, P., Stathakis, S., Gutierrez, A.N., Esquivel, C., Mavroidis, P. and Papanikolaou, N. (2012) Evaluation of PTW Seven29 for Tomotherapy Patient-Specific Quality Assurance and Comparison with ScandiDos Delta. Journal of Medical Physics, 37, 72-80.
https://doi.org/10.4103/0971-6203.94741

[6]   Defoor, D.L., Vazquez-Quino, L.A., Mavroidis, P., Papanikolaou, N. and Stathakis, S. (2015) Anatomy-Based, Patient-Specific VMAT QA Using EPID or MLC Log Files. Journal of Applied Clinical Medical Physics, 16, 206-215.
https://doi.org/10.1120/jacmp.v16i3.5283

[7]   Mijnheer, B., Olaciregui-Ruiz, I., Rozendaal, R., Spreeuw, H., van Herk, M. and Mans, A. (2015) Current Status of 3D EPID-Based in Vivo Dosimetry in The Netherlands Cancer Institute. Journal of Physics: Conference Series, 573, Article ID: 012014.
https://doi.org/10.1088/1742-6596/573/1/012014

[8]   Rowshanfarzad, P., Mcgarry, C.K., Barnes, M.P., Sabet, M. and Ebert, M.A. (2014) An EPID-Based Method for Comprehensive Verification of Gantry EPID and the MLC Carriage Positional Accuracy in Varian Linacs during Arc Treatments. Radiation Oncology, 9, 249.
https://doi.org/10.1186/s13014-014-0249-8

[9]   Bojechko, C., Phillps, M., Kalet, A. and Ford, E.C. (2015) A Quantification of the Effectiveness of EPID Dosimetry and Software-Based Plan Verification Systems in Detecting Incidents in Radiotherapy. Medical Physics, 42, 5363-5369.
https://doi.org/10.1118/1.4928601

[10]   Vazquez Quino, L.A., Chen, X., Fitzpatrick, M., Shi, C., Stathakis, S., Gutierrez, A., et al. (2014) Patient Specific Pre-Treatment QA Verification Using an EPID Approach. Technology in Cancer Research & Treatment, 13, 1-10.
https://doi.org/10.7785/tcrt.2012.500351

[11]   Huang, G., Medlam, G., Lee, J., Billingsley, S., Bissonnette, J.P., Ringash, J., et al. (2005) Error in the Delivery of Radiation Therapy: Results of a Quality Assurance Review. International Journal of Radiation Oncology, Biology, Physics, 61, 1590-1595.
https://doi.org/10.1016/j.ijrobp.2004.10.017

[12]   Mans, A., Wendling, M., McDermott, L.N., Sonke, J.J., Tielenburg, R., Vijlbrief, R., et al. (2010) Catching Errors with in Vivo EPID Dosimetry. Medical Physics, 37, 2638-2644.
https://doi.org/10.1118/1.3397807

[13]   Patton, G.A., Gaffney, D.K. and Moeller, J.H. (2003) Facilitation of Radio Therapeutic Error by Computerized Record and Verify Systems. International Journal of Radiation Oncology, Biology, Physics, 56, 50-57.
https://doi.org/10.1016/S0360-3016(02)04418-8

[14]   Wendling, M., McDermott, L.N., Mans, A., Sonke, J.J., van Herk, M. and Mijnheer, B.J. (2009) A Simple Back Projection Algorithm for 3D in Vivo EPID Dosimetry of IMRT Treatments. Medical Physics, 36, 3310-3321. |
https://doi.org/10.1118/1.3148482

[15]   Mans, A., Remeijer, P., Olaciregui-Ruiz, I., Wendling, M., Sonke, J.J., Mijnheer, B., et al. (2010) 3D Dosimetric Verification of Volumetric-Modulated Arc Therapy by Portal Dosimetry. Radiotherapy & Oncology, 94, 181-187.
https://doi.org/10.1016/j.radonc.2009.12.020

[16]   Olaciregui-Ruiz, I., Rozendaal, R., Mijnheer, B., van Herk, M. and Mans, A. (2013) Automatic in Vivo Portal Dosimetry of All Treatments. Physics in Medicine & Biology, 58, 8253-8264.
https://doi.org/10.1088/0031-9155/58/22/8253

[17]   Fidanzio, A., Azario, L., Greco, F., Cilla, S. and Piermattei, A. (2015) Routine EPID in Vivo Dosimetry in a Reference Point for Conformal Radiotherapy Treatments. Physics in Medicine & Biology, 60, N141-N150.
https://doi.org/10.1088/0031-9155/60/8/N141

[18]   Rozendaal, R.A., Mijnheer, B.J., Hamming-Vrieze, O., Mans, A. and van Herk, M. (2015) Impact of Daily Anatomical Changes on EPID-Based in Vivo Dosimetry of VMAT Treatments of Head-and-Neck Cancer. Radiotherapy & Oncology, 116, 70-74.
https://doi.org/10.1016/j.radonc.2015.05.020

[19]   Bailey, D.W., Kumaraswamy, L., Bakhtiari, M., Malhotra, H.K. and Podgorsak, M.B. (2012) EPID Dosimetry for Pretreatment Quality Assurance with Two Commercial Systems. Journal of Applied Clinical Medical Physics, 13, 82-99.
https://doi.org/10.1120/jacmp.v13i4.3736

[20]   Royer, P., Marchesi, V., Rousseau, V., Buchheit, I., Wolf, D., Peiffert, D., et al. (2014) Evaluation of Transit in Vivo Dosimetry Using Portal Imaging and Comparison with Measurements Using Diodes. Cancer/Radiothérapie, 18, 183-190.
https://doi.org/10.1016/j.canrad.2014.03.006

[21]   Ford, E.C., Terezakis, S., Souranus, A., Harris, K., Gay, H. and Mutic, S. (2012) Quality Control Quantification (QCQ): A Tool to Measure the Value of Quality Control Checks in Radiation Oncology. International Journal of Radiation Oncology, Biology, Physics, 84, e263-e269.
https://doi.org/10.1016/j.ijrobp.2012.04.036

[22]   Tarutani, K., Tanooka, M., et al. (2019) Improved Error Detection Using a Divided Treatment Plan in Volume Modulated Arc Therapy. Reports of Practical Oncology and Radiotherapy, 24, 133-141.

[23]   Low, D.A. and Dempsey, J.F. (2003) Evaluation of the Gamma Dose Distribution Comparison Method. Medical Physics, 30, 2455-2464.
https://doi.org/10.1118/1.1598711

[24]   Chung, E., Kwon, D., Park, T., Kang, H. and Chung, Y. (2018) Clinical Implementation of Dosimetry Check™ for TomoTherapy® Delivery Quality Assurance. Journal of Applied Clinical Medical Physics, 19, 193-199.
https://doi.org/10.1002/acm2.12480

 
 