Dosimetric Comparison of Integral Radiation Dose: Anisotropic Analytical Algorithm and Acuros XB in Breast Radiotherapy
Abstract: The impact of the difference between Anisotropic Analytical Algorithm (AAA) and Acuros XB (AXB) in breast radiotherapy is not clearly due to different uses and further research is required to explain this effect. The aim of this study is to investigate the contribution of calculation differences between AAA and AXB to the integral radiation dose (ID) on critical organs. Seven field intensity modulated radiotherapy (IMRT) plans were generated using with AAA and AXB algorithms for twenty patients with early stage left breast cancer after breast conserving surgery. Volumetric and dosimetric differences, as well as, the Dmean, V5, V20 doses of the left and right-sided lung, the Dmean, V10, V20, V30 doses of heart and the Dmean, V5, V10 doses of the contralateral breast were investigated. The mean dose (Dmean), V5, V20 doses of the left-sided lung, the Dmean, V5, V10 doses of right-sided lung, the Dmean, V10, V20, V30 doses of heart and the Dmean, V5, V10 doses of the contralateral breast were found to be significantly higher with AAA. In this research integral dose was also higher in the AAA recalculated plan and the AXB plan with the average dose as follows left lung 2%, heart 2%, contralateral breast 8%, contralateral lung 4% respectively. Our study revealed that the calculation differences between Acuros XB (AXB) and Anisotropic Analytical Algorithm (AAA) in breast radiotherapy caused serious differences on the stored integral doses on critical organs. In addition, AXB plans showed significantly dosimetric improvements in multiple dosimetric parameters.
Cite this paper: Cakir, A. and Akgun, Z. (2019) Dosimetric Comparison of Integral Radiation Dose: Anisotropic Analytical Algorithm and Acuros XB in Breast Radiotherapy. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 8, 57-67. doi: 10.4236/ijmpcero.2019.82006.
References

[1]   D’Souza, W.D. and Rosen, I.I. (2003) Nontumor Integral Dose Variation in Conventional Radiotherapy Treatment Planning. Medical Physics, 30, 2065-2071.
https://doi.org/10.1118/1.1591991

[2]   Tillikainen, L., Siljamaki, S., Helminen, H., Alakuijala, J. and Pyyry, J. (2007) Determination of Parameters for a Multiple-Source Model of Megavoltage Photon Beams Using Optimization Methods. Physics Medicine in Biology, 52, 1441-1467.
https://doi.org/10.1088/0031-9155/52/5/015

[3]   Breitman, K., Rathee, S., Newcomb, C., Murray, B., Robinson, D., Field, C., et al. (2007) Experimental Validation of the Eclipse AAA Algorithm. Journal of Applied Clinical Medical Physics, 10, 76-92.

[4]   Tillikainen, L., Helminen, H., Torsti, T., Siljamaki, S., Alakuijala, J., Pyyry, J. and Ulmer, W. (2008) A 3D Pencil-Beam-Based Superposition Algorithm for Photon Dose Calculation in Heterogeneous Media. Physics in Medicine and Biology, 53, 3821-3839.
https://doi.org/10.1088/0031-9155/53/14/008

[5]   Van Esch, A., Tillikainen, L., Pyykkonen, J., Tenhunen, M., et al. (2006) Testing of the Analytical Anisotropic Algorithm for Photon Dose Calculation. Medical Physics, 33, 4130-4148.
https://doi.org/10.1118/1.2358333

[6]   Robinson, D.M. (2008) Inhomogeneity Correction and the Analytical Anisotropic Algorithm. Journal of Applied Clinical Medical Physics, 9, 112-122. https://doi.org/10.1120/jacmp.v9i2.2786

[7]   Vassiliev, O., Wareing, T., McGhee, J., Failla, G., Salehpour, M. and Mourtada, F. (2010) Validation of a New Grid-Based Blotzmann Equation Solver for Dose Calculation in Radiotherapy with Photon Beams. Physics Medicine in Biology, 55, 581-598.

[8]   Hoffmann, L., Jorgensen, M., Muren, L. and Petersen, J. (2012) Clinical Validation of the Acuros XB Photon Dose Calculation Algorithm, a Grid-Based Boltzmann Equation Solver. Acta Oncologica. 51, 376-385.
https://doi.org/10.3109/0284186X.2011.629209

[9]   Fogliata, A., Nicolini G., Clivio, A., Vanetti, E. and Cozzi, L. (2011) Dosimetric Evaluation of Acuros XB Advanced Dose Calculation Algorithm in Heterogeneous Media. Radiation Oncology, 6, 82. https://doi.org/10.1186/1748-717X-6-82

[10]   Han, T., Mikell, J., Salehpour, M. and Mourtada, F.(2011) Dosimetric Comparison of Acuros XB Deterministic Radiation Transport Method with Monte Carlo and Model-Based Convolution Methods in Heterogeneous Media. Medical Physics, 38, 2651-2664.
https://doi.org/10.1118/1.3582690

[11]   Huang, B., Wu, L.L., Pei, X.L. and Chen, C.Z. (2015) Dose Calculation of Acuros XB and Anisotropik Analytical Algorithm in Lung Stereotactic Body Radiotherapy Treatment with Flattening Filter Free Beams and Potential Role of Calculation Grid Size. Radiation Oncology, 10, 53. https://doi.org/10.1186/s13014-015-0357-0

[12]   Kan, M., Leung, L. and Yu, P. (2012) Verification and Dosimetric Impact of Acuros XB Algorithm on Intensity Modulated Stereotactic Radiotherapy for Locally Persistent Nasopharyngeal Carcinoma. Medical Physics, 39, 4705-4714. https://doi.org/10.1118/1.4736819

[13]   Chung, H., Jin, H., Palta, J., Suh, T.S. and Kim, S. (2006) Dose Variations with Varying Calculation Grid Size in Head and Neck IMRT. Physics Medicine in Biology, 51, 4841-4856.

[14]   Mittauer, K., Lu, B., Yan, G., Kahler, D., Gopal, A., Amdur, R., et al. (2013) A Study of IMRT Planning Parameters on Planning Efficiency, Delivery Efficiency, and Plan Quality. Medical Physics, 40, Article ID: 061704. https://doi.org/10.1118/1.4803460

[15]   Ong, C.L., Cuijpers, J.P., Senan, S., Slotman, B.J. and Verbakel, W.F. (2011) Impact of the Calculation Resolution of AAA for Small Fields and RapidArc Treatment Plans. Medical Physics, 38, 4471-4479. https://doi.org/10.1118/1.3605468

[16]   Bush, K., Gagne, I.M., Zavgorodni, S., Ansbacher, S. and Beckham, W. (2011) Dosimetric Validation of Acuros XB with Monte Carlo Methods for Photon Dose Calculations. Medical Physics, 38, 2208-2221. https://doi.org/10.1118/1.3567146

[17]   Han, T., Mourtada, F., Kisling, K., Mikell, J., Followill, D. and Howell, R. (2012) Experimental Validation of Deterministic Acuros XB Algorithm for IMRT and VMAT Dose Calculation with Radiological Physics Center’s Head and Neck Phantom. Medical Physics, 39, 2193-2202. https://doi.org/10.1118/1.3692180

[18]   Fogliata, A., Nicolini, G., Clivio, A., Vanetti, E. and Cozzi, L. (2011) On the Dosimetric Impact of Inhomogeneity Management in the Acuros XB Algorithm for Breast Treatment. Radiation Oncology, 6, 103. https://doi.org/10.1186/1748-717X-6-103

[19]   Padmanaban, S., Warren, S., Walsh, A., Partridge, M. and Hawkins, A. (2014) Comparison of Acuros (AXB) and Anisotropic Analytical Algorithm (AAA) for Dose Calculation in Treatment of Oesophageal Cancer: Effects on Modelling Tumour Control Probability. Radiation Oncology, 9, 286.

 
 
Top