Environmental Assessment and Dielectric Performances of the Secondary Electrical Insulation in Low Voltage Motors Impregnated by Different Techniques
Abstract: A recent technique, using to potentially replace the conventional impregnating one in low voltage electric motors, has been studied in this communication. The conventional technique that uses both primary and secondary insulations; i.e.: enamel and varnish, has been compared to this recent technique which only uses one component, i.e.: self-bonding wires. Self-bonding wires polymerization is very quick compared to that of the conventional technique. Environmental impact and both dielectric and mechanical properties of these two techniques have been estimated and compared. The goal is to estimate if this recent technique has not only a better environmental footprint but also good technical properties. The dielectric properties that have been measured are the dielectric strength and the lifetime under pulse voltage while mechanical consists in measuring the bonding strength that is crucial for impregnation. For that purpose, a Life Cycle Assessment (LCA) that can simultaneously evaluatenumerous impacts on ground, water and air, has been performed. The results show clearly that the recent technique significantly reduces the environmental footprint. Both mechanical and dielectric properties are then compared and analyzed.
Cite this paper: Nguyen, M. , Dario, S. , Malec, D. , Mary, D. , Cambronne, J. , Prunel, D. and Orgelet, J. (2017) Environmental Assessment and Dielectric Performances of the Secondary Electrical Insulation in Low Voltage Motors Impregnated by Different Techniques. Engineering, 9, 860-873. doi: 10.4236/eng.2017.910051.
References

[1]   Boughanmi, W., Manata, J.P. and Roger, D. (2012) Contribution of LCA Approach to the Choice of Rotating Electrical Machines for Environmental Impact Minimization. Proceeding of the XXth International Conference on Electrical Machines, 122-128.

[2]   IEC 60034-18-41 Standard (2014) Rotating Electrical Machines—Part 18-41: Partial Discharge Free Electrical Insulation Systems (Type I) used in Rotating Electrical Machines Fed from Voltage Converters—Qualification and Quality Control Tests.

[3]   Anton, A. (2009) Enemaled Wires and Primary Insulation. Technique de l’ingénieur, [D2330] in Converters and Rotating Machines.

[4]   Weijun, Y., Bultemeier, K., Barta, D. and Floryan, D. (1997) Improved Magnet Wire for Inverter-Fed Motors. Proceeding on Electrical Insulation Conference and Electrical Manufacturing & Coil Winding Technology Conference, 379-382.

[5]   Kikuchi, H., Yukimori, Y. and Itonaga, S. (2002) Inverter Surge Resistant Enameled Wire Based on Nano-Composite Insulating Material. Hitachi Cable Review, 21, 55-62.

[6]   Nguyen, M.Q., Malec, D., Mary, D., Werynski, P., Gornicka, B., Therese, L. and Guillot, P. (2010) Silica Nanofilled Varnish Designed for the Electrical Insulation of Low Voltage Inverter-Fed Motors. IEEE Transactions on Electrical Insulation, 17, 1349-1356.
https://doi.org/10.1109/TDEI.2010.5595535

[7]   NEMA MW 1000 Standard (2015) Magnet Wire.

[8]   ASTM D149-97 (2004) Standard Methods of Test for Dielectric Breakdown Voltage and Dielectric Strength of Electrical Insulating Materials at Commercial Power Frequencies.

[9]   IEC 60851-3 Standard (2009) Winding Wires—Test methods—Part 3: Mechanical Properties.

 
 