Back
 OALibJ  Vol.1 No.7 , October 2014
Determination of Zoledronic Acid and Four Common Anions in Zoledronic Acid Injection by Gradient Ion Chromatography with a Self-Regeneration Suppressor
Abstract: A simple method to determine zoledronic acid and impurities in drug by ion chromatography with conductivity detection was developed. Target analytes have been sufficiently separated from each other on an Ionpac AS19 by using potassium hydroxide as eluent with a self-regeneration suppressor. This novel proposed method enables direct analysis of zoledronic acid in injection sample and provides good resolution. This novel method also exhibits satisfactory precision (less than 1.68%) and accuracy (90.0% - 110.0%), good linearity (r2 = 0.9993 - 0.9999) and sufficient sensitivity (0.007 - 0.030 μg/mL). It can be easily and conveniently adopted for the routine quality control analysis.
Cite this paper: Chen, M. and Ye, M. (2014) Determination of Zoledronic Acid and Four Common Anions in Zoledronic Acid Injection by Gradient Ion Chromatography with a Self-Regeneration Suppressor. Open Access Library Journal, 1, 1-5. doi: 10.4236/oalib.1100827.
References

[1]   Robert, E. (2004) Bisphosphonates: Clinical Experience. Oncologist, 9, 14.

[2]   Major, P.P. and Cook, R. (2002) Efficacy of Bisphosphonates in the Management of Skeletal Complications of Bone Metastases and Selection of Clinical Endpoints. American Journal of Clinical Oncology, 25, 10.
http://dx.doi.org/10.1097/00000421-200212001-00003

[3]   Xie, Z., Jiang, Y. and Zhang, D.Q. (2006) Simple Analysis of four Bisphosphonates Simultaneously by Reverse Phase Liquid Chromatography Using N-Amylamine as Volatile Ion-Pairing Agent. Journal of Chromatography A, 1104, 173.
http://dx.doi.org/10.1016/j.chroma.2005.11.113

[4]   Rao, B.M., Srinivasu, M.K., Rani, C.P., kumar, S.S., Kumar, P.R., Chandrasekharc, K.B. and Veerender, M. (2005) A Validated Stability Indicating Ion-Pair RP-LC Method for Zoledronic Acid. Journal of Pharmaceutical and Biomedical Analysis, 39, 781.
http://dx.doi.org/10.1016/j.jpba.2005.04.012

[5]   Lovdahl, M.J. and Pietrzyk, D.J. (1999) Anion-Exchange Separation and Determination of Bisphosphonates and Related Analytes by Post-Column Indirect Fluorescence Detection. Journal of Chromatography A, 850, 143.
http://dx.doi.org/10.1016/S0021-9673(99)00622-6

[6]   Zhang, J.J. and Zhu, Y. (2007) Determination of Betaine, Choline and Trimethylamine in Feed Additive by Ion-Exchange Liquid Chromatography/Non-Suppressed Conductivity Detection. Journal of Chromatography A, 1170, 114.
http://dx.doi.org/10.1016/j.chroma.2007.09.014

[7]   Chen, M.L., Yan, W., Chen, Y.X., Jia, Z.S. and Zhu, Y. (2007) Determination of Impurities in Flame Retardant Monomer 2-Carboxyl Ethyl(Phenyl) Phosphinic Acid by Ion Chromatography. Journal of Chromatography A, 1155, 47.
http://dx.doi.org/10.1016/j.chroma.2007.02.045

 
 
Top