OJAppS  Vol.5 No.10 , October 2015
Development of Multiphoton Ionization Technique for Detection of Polycyclic Aromatic Hydrocarbon (PAH) in Solution
ABSTRACT
A simple low-cost system for detection of polycyclic aromatic hydrocarbon (PAH) in solution based on multiphoton ionization configuration is designed using a circulating ionization cell of 0.1 × 2 × 5 mm dimension with quartz optical window. Fourth harmonic emission of Nd:YAG laser (266 nm, 6 ns, 10 Hz, and 2 mJ) and second harmonic generation of distributed feedback dye laser (278 - 286 nm, 20 ps, 10 Hz, and 300 μJ) were used as the ionization source. A high voltage of 800 V was applied to separate the ions after ionization. The photocurrent includes a sharp peak and a broad tail indexed to electron and ion currents, respectively. The lowest concentration of anthraxcene (C14H10) in order of few nano-grams per milliliter was detected by this multiphoton ionization configuration.

Cite this paper
Quang, H. , Vu, D. , Trong, N. and Imasaka, T. (2015) Development of Multiphoton Ionization Technique for Detection of Polycyclic Aromatic Hydrocarbon (PAH) in Solution. Open Journal of Applied Sciences, 5, 595-599. doi: 10.4236/ojapps.2015.510058.
References
[1]   Oser, H., Copic, K., Coggiola, M.J., Faris, G.W. and Crosly, D.R. (2001) Congener-Specific Detection of Dioxins Using Jet-REMPI. Chromophere, 43, 469.

[2]   Lacorte, S. and Fernandez-Alba, A.R. (2006) Time of Flight Mass Spectrometry Applied to the Liquid Chromatographic Analysis of Pesticides in Water and Food. Mass Spectrometry Reviews, 25, 866-880.
http://dx.doi.org/10.1002/mas.20094

[3]   Wei, J., Zhang, B., Fang, L., Zhang, L. and Cai, J. (1998) REMPI Time-of-Flight Mass Spectra of C2H7N Isomers. Optics Communications, 156, 331-336. http://dx.doi.org/10.1016/S0030-4018(98)00457-X

[4]   Schwarz, J., Rambo, P. and Diels, J.C. (2001) Measurements of Multiphoton Ionization Coefficients with Ultrashort Ultraviolet Laser Pulses. Applied Physics B, 72, 343.
http://dx.doi.org/10.1007/s003400100496

[5]   Matsui, T., Fukazawa, K., Fujimoto, M. and Imasaka, T. (2012) Analysis of Persistent Organic Pollutants at Sub- Femtogram Levels Using a High-Power Picosecond Laser for Multiphoton Ionization in Conjunction with Gas Chromatography/Time-of-Flight Mass Spectrometry. Analytical Science, 28, 445.

[6]   Yamada. S. (1991) A Submicroliter Transparent Cell for Laser Multiphoton Ionization Detection in Solution. Analytical Chemistry, 63, 1894-1897. http://dx.doi.org/10.1021/ac00017a041

[7]   Yamada. S. (2009) Application of Strong Interactions between Photons and Molecules to Analytical Sciences. Analytical Science, 29, 1059.

[8]   Hoa, D.Q., Duong, V., Long, P. and Nhung, T.H. (2008) Generation Short-Pulse Laser by Using a Quenched Distributed Feedback Dye Laser. Journal of the Korean Physical Society, 53, 3823.

[9]   Van den Bron, A.J., Kapelios, M., et al. (2005) Photodissociation and Photoionization of Pyrrole Following the Multiphoton Excitation at 243 and 364 nm. Physical Chemistry Chemical Physics, 5, 892.

[10]   Kjellberg, M., Bulgakov, A.V., Goto, M., Johansson, O. and Kassen, K. (2010) Femtosecond Electron Spectroscopy of Coronene, Benzo[GHI]perylene, and Anthracene. The Journal of Chemical Physics, 133, Article ID: 074308. http://dx.doi.org/10.1063/1.3466925

 
 
Top