JMP  Vol.6 No.7 , June 2015
Evaluate Shielding Design of the Brachytherapy Unit by Using Monte Carlo Simulation Code
ABSTRACT
Shielding design is necessary for brachytherapy treatment room in order to protect the general public and employees. The main objective of this study was to investigate whether the protective unit of our Brachytherapy Centre provided adequate protection to the health and safety assessment of radiobiological impact. In this study, we estimated the effect of radiobiological protection from a single Ir-192 brachytherapy source in Brachytherapy center by using MCNP5 Monte Carlo measurements. The room was based on the design specifications for the HDR 192 Ir treatment was modeled. The estimated dose rate range for HDR 192 Ir and public buildings is (0.45 - 0.64): (micro sivert) μSv/hour. Dose rates measured data for the current setup Brachytherapy HDR unit was approved and agreed quiet well with recommendation of International Atomic Energy Agency. The measured dose rate for public areas and controlled areas, compared with the reference value of 7.5 μSv/h and 0.5 μSv/h and concluded that we have enough shielding to the source but an over estimate with experimental measurements had been seen.

Cite this paper
Jaberi, R. , Hadi Gholami, M. , Sedighi Pashaki, A. and Khoshghadam, A. (2015) Evaluate Shielding Design of the Brachytherapy Unit by Using Monte Carlo Simulation Code. Journal of Modern Physics, 6, 902-911. doi: 10.4236/jmp.2015.67094.
References
[1]   Cashwell, E.D. and Everett, C.J. (1959) A Practical Manual on the Monte Carlo Method for Random Walk Problems. Pergamon Press, Oxford.

[2]   https://mcnpx.lanl.gov/opendocs/misc/FeaturesList

[3]   Los Alamos National Laboratory, New Mexico, United States. https://mcnp.lanl.gov

[4]   L.A.N. Laboratory (2000) Monte Carlo N-Particle Transport Code System.

[5]   Alain Gerbaulet RP, Harm Meertens, Erik Van Limbergen (2001) The GEC ESTRO Handbook of Brachytherapy. ESTRO, Brussels.

[6]   Arthur B. Chilton, Richard E. (1984) Principle of Radiation Shielding. Prentice Hall, Kanas.

[7]   Joslin, A. and Hall, E.J. (2001) Principle and Practice of Brachytherapy Using after Loading Systems. Joanna Koster, London.

[8]   (1996) International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources. IAEAsafety Series, Vienna.

[9]   (2006) Radiation Oncology Physics: A Handbook for Teachers and Students. IAEA, Vienna.

[10]   (1997) The Design of Radiotherapy Treatment Room Facilities. IPEM, York.

[11]   (2006) Radiation Protection in the Design of Radiotherapy Facilities, Safety Reports Series No. 47. International Atomic Energy Agency, Vienna.

[12]   Elert, G. (2008) Density of Wood. Shirley Lam.

[13]   Schwarz, R.A.S.A.L. and Carter, L.L. (2008) MCNP/MCNPX Visual Editor Computer Code Manual.

[14]   Team, X.-M.C. (2008) A General Monte Carlo N-Particle Transport Code. Version 5, Los Alamos National Laboratory, New Mexico, United States.

 
 
Top