Commissioning and Optimization of a Total Skin Electron Therapy Technique Using a High Dose Rate Electron Facility
ABSTRACT
Total skin electron therapy (TSET) is used for the treatment of Mycosis Fungoides. Several tech-niques have been developed, in order to achieve homogeneous dose distribution over the complete body surface. To implement a TSET technique, one has to optimize a variety of parameters. Monte Carlo simulation of TSET can facilitate this optimization. The aim of this study was to commission and optimize a TSET technique using the 4 and 6 MeV electron and the high dose rate facility on the Elekta Precise accelerator. The EGS4nrc/BEAMnrc Monte Carlo code was used. The beam data were calculated and measured at two different scoring planes for a single beam. The Model was validated by comparing the simulation with measurements. Two different vertical angles were used to obtain a uniform dose. The angle was optimized for best dose uniformity. The Rando phantom is placed on a rotating platform and rotates 60 degrees apart to facilitate the six patient position orientations. The doses delivered in a phantom by complete treatment were measured with Kodak EDR2 films and TLDs. The dose distribution varied among various scanning directions by 2 - 3 mm and 3 - 4 mm for 4 and 6 MeV respectively. The composite percentage depth dose of all six dual fields for the 4 and 6 MeV yielded an R80 of ~4 mm and ~6 mm, respectively. Dose uniformity was ±6% for 4 MeV and ±5% for 6 MeV. The bremsstrahlung contamination was 0.9% - 1.3%. Good agreements were found with published literature and inline with international protocols.

Cite this paper
A. M. Yousif, Y. and A. Willemse, C. (2015) Commissioning and Optimization of a Total Skin Electron Therapy Technique Using a High Dose Rate Electron Facility. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 4, 197-207. doi: 10.4236/ijmpcero.2015.43024.
References
[1]   Abel, E., Sendagrota, E., Hope, R. and Hu, H. (1987) PUVA TREATMENT of erthroderimic and Plaque-Type Mycosis Fungoides: Ten Year Follow-Up. Archives of Dermatology, 123, 897-901.
http://dx.doi.org/10.1001/archderm.1987.01660310065016

[2]   Maingon, P., et al. (2002) Radiotherapy of Advanced Mycosis Fungoides: Indications and Results of Total Skin Electron Beam and Photon Beam Irradiation. Radiotherapy and Oncology, 54, 73-78.
http://dx.doi.org/10.1016/S0167-8140(99)00162-0

[3]   Heserich, R., Richardoson, H. and Grant, J. (1990) Remission of Lesions in Mycosis Fungoides Following Topical Applications of Nitrogen Mustard. Cleveland Clinic, 26, 144-147.
http://dx.doi.org/10.3949/ccjm.26.3.144

[4]   Hope, R.T., et al. (1979) Electron-Beam Therapy for Mycosis Fungoides: The Stanford University Experience. Cancer Treatment Reports, 63, 691-700.

[5]   AAPM, American Association of Physicists in Medicine (1988) Total Skin Electron Therapy: Technique and Dosimetry. AAPM Report No. 23, American Institute of Physics, New York.

[6]   Khan, F.M. (2003) The Physics of Radiation Therapy. 2nd Edition, Williams & Wilkins, Maryland.

[7]   So-Yeon, P., Beom, A.I., Jong, M.P., Sung-Joon, Y., Il, H.K. and Jung-in, K. (2014) Dosimetric Comparison of 4 MeV and 6 MeV Electron Beams for Total Skin Irradiation. 197.

[8]   Lucic, F., Beatriz Sánchez-Nieto, B., Paola Caprile, P., Zelada, G. and Goset, K. (2013) Dosimetric Characterization and Optimization of a Customized Stanford Total Skin Electron Irradiation (TSEI) Technique. Journal of Applied Clinical Medical Physics, 14, 1-12.

[9]   Faddegon, B.A., Perl, J. and Asai, M. (2008) Monte Carlo Simulation of Large Electron Fields. Physics in Medicine Biology, 53, 1497-1510.
http://dx.doi.org/10.1088/0031-9155/53/5/021

[10]   Chen, Z., Agostinelli, A.G., Wilson, L.D. and Nath, R. (2004) Matching the Dosimetry Characteristics of a Dual-Field Stanford Technique to a Customized Single-Field Stanford Technique for Total Skin Electron Therapy. International Journal of Radiation Oncology * Biology * Physics, 59, 872-885.
http://dx.doi.org/10.1016/j.ijrobp.2004.02.046

[11]   Faddegon, B., Balogh, J., Mackenzie, R. and Scora, D. (1988) Clinical Considerations of Monte Carlo for Electron Radiotherapy Treatment Planning. Radiation Physics and Chemistry, 53, 217-227.
http://dx.doi.org/10.1016/S0969-806X(98)00103-0

[12]   Ma, C.-M. and Jiang, S.B. (1999) Monte Carlo Modeling of Electron Beams from Medical Accelerators. Physics in Medicine and Biology, 44, 157-187.
http://dx.doi.org/10.1088/0031-9155/44/12/201

[13]   Ye, S.-J., Pareek, P.N., Spencer, S., Duan, J. and Brezovich, I.A. (2005) Monte Carlo Techniques for Scattering Foil Design and Dosimetry in Total Skin Electron Irradiations. Medical Physics, 32, 1460-1468.
http://dx.doi.org/10.1118/1.1924368

[14]   Antolak, J.A., Bieda, M.R. and Hogstrom, K.R. (2002) Using Monte Carlo Methods to Commission Electron Beams: A Feasibility Study. Medical Physics, 29, 771-786.
http://dx.doi.org/10.1118/1.1469626

[15]   Bieda, M.R., Antolak, J.A. and Hogstrom, K.R. (2001) The Effect of Scattering Foil Parameters on Electron-Beam Monte Carlo Calculations. Medical Physics, 28, 2527-2534.
http://dx.doi.org/10.1118/1.1420387

[16]   Faj, D., Vrtar, M., Krajina, Z., Jurkovi, S. and Margareti, D. (2003) Model of Total Skin Electron Treatment Using the “Six-Dual-Field” Technique. Collegium Antropologicum, 27, 713-721.

[17]   Pavón, E.C., Sánchez-Doblado, F., Leal, A., Capote, R., Lagares, J.I., Perucha, M. and Arráns, R. (2003) Total Skin Electron Therapy Treatment Verification: Monte Carlo Simulation and Beam Characteristics of Large Nonstandard Electron Fields. Physics in Medicine and Biology, 48, 2783-2796.
http://dx.doi.org/10.1088/0031-9155/48/17/304

[18]   Precise Operators Manual (2003) Chapter 11, High Dose Rate Electron Therapy (HDRE).

[19]   Rogers, D.W.O., Walters, B. and Kawrakow, I. (2006) BEAMnrc Users Manual. National Research Council of Canada. NRCC Report, PIRS-0509(A)RevK, NRC, Ottawa.

[20]   Walters, B., Kawrakow, I. and Rogers, D.W.O. (2006) DOSXYZnrc User’s Manual. NRCC Report PIRS-794RevB, NRC, Ottawa.

[21]   Ma, C.-M. and Rogers, D.W.O. (2006) BEAMDP User’s Manual. NRCC Report PIRS-0509(C)RevA, NRC, Ottawa.

[22]   Gerbi, B.J. and Dimitroyannis, D.A. (2003) The Response of Kodak EDR2 Film in High-Energy Electron Beams. Medical Physics, 30, 2703-2705.
http://dx.doi.org/10.1118/1.1607505

[23]   Cox, R.S., Heck, R.J., Fessenden, P., Karzmark, C.J. and Rust, D.C. (1989) Development of Total Skin Electron Therapy at Two Energies. International Journal of Radiation Oncology*Biology*Physics, 18, 659-669.
http://dx.doi.org/10.1016/0360-3016(90)90075-U

[24]   Turner, J.R., Hugtenburg, R.P. and Wynne, C.J. (1995) Total Skin Electron Therapy at Two Energies on a Linear Accelerator. Australasian Physical and Engineering Sciences in Medicine, 18, 208-220.

[25]   IDL, EXELIS Visual Information Solutions.
http://www.exelisvis.com

 
 
Top