WJCS  Vol.5 No.1 , January 2015
Report on Acute Aortic Dissection Type A
ABSTRACT
Background: Acute aortic dissection is a common life-threatening disorder affecting the aorta. The immediate mortality rate in aortic dissection is as high as 1% per hour over the first several hours, making early diagnosis and treatment critical for survival. Case presentation: We are presenting a case of Stanford Type A aortic dissection in a 58-year-old male patient with a history of hypertension. He arrived at the emergency department (ED) with diagnosed acute coronary syndrome a few hours after a sudden and severe worsening of his epigastric pain. Interesting case where the dissection starts from the orifice of the right coronary artery, occupies the aortic valve. Conclusion: Predictors of follow-up this cause mortality reflect patient history variables as opposed to in-hospital parameters or in-hospital complications, which may be explained by the successful in-hospital treatment of the acute dissection.

Cite this paper
Simoglou, C. , Konstantinou, F. , Mikroulis, D. , Eleftheriadis, S. and Bougioukas, G. (2015) Report on Acute Aortic Dissection Type A. World Journal of Cardiovascular Surgery, 5, 1-5. doi: 10.4236/wjcs.2015.51001.
References
[1]   Knaut, A.L. and Cleveland, J.C. (2003) Aortic Emergencies. Emergency Medicine Clinics of North America, 21, 817- 845.
http://dx.doi.org/10.1016/S0733-8627(03)00063-4

[2]   Rushid, J., Eisenberg, M.J. and Topol, E.J. (1996) Cocaine-Indueed Aortic Dissection. American Heart Journal, 132, 1301-1304.
http://dx.doi.org/10.1016/S0002-8703(96)90486-X

[3]   Nienaber, C.A., von Kodolitsh, Y. and Nikolas, V. (1993) The Diagnosis of Thoracic Aortic Dissection by Noninvasive Imaging Procrdures. The New England Journal of Medicine, 328, 1-9.
http://dx.doi.org/10.1056/NEJM199301073280101

[4]   Vasile, N., Mathieu, D. and Keita, K. (1986) Computed Tomography of Thoracic Aortic Dissection: Accuracy and Pitfalls. Journal of Computer Assisted Tomography, 10, 211-215.
http://dx.doi.org/10.1097/00004728-198603000-00008

[5]   Kawahito, K., Adachi, H., Yamaguchi, A. and Ino, T. (2001) Preoperative Risk Factors for Hospital Mortality in Acute Type A Aotic Dissection. The Annals of Thoracic Surgery, 71, 1239-1243.
http://dx.doi.org/10.1016/S0003-4975(00)02654-0

[6]   Fleming, C., Whitlock, E.P., Beil, T.L. and Lederle, F.A. (2005) Screening for Abdominal Aortic Aneurysm: A Best- Evidence Systematic Review for the US Preventive Services Task Force. Annals of Internal Medicine, 142, 203-211.
http://dx.doi.org/10.7326/0003-4819-142-3-200502010-00012

[7]   Liao, M.F., Jing, Z.P. and Bao, J.M. (2006) Role of Nitrix Oxide and Inducible Nitrix Oxide Synthase in Human Abdominal Aortic Aneurysms: A Preliminary Study. Chinese Medical Journal, 119, 312.

[8]   Tsai, T.T., Nienaber, C.A. and Eagle, K.A. (2005) Acute Aortic Syndromes. Circulation, 112, 3802-3813.
http://dx.doi.org/10.1161/CIRCULATIONAHA.105.534198

 
 
Top