The Precise Methods for the Measurement of Collimator Hole Angulation and Center of Rotation of SPECT by Adaptive Quality Control Phantom
ABSTRACT
The Adaptive Quality Control Phantom (AQCP) is a computer-controlled phantom which positions and moves a radioactive source in the Field of View (FOV) of an imaging nuclear medicine device on a definite path to produce a spatial distribution of gamma rays to perform QC Tests such as the Collimator Hole Angulation (CHA) and the Center of Rotation (COR) of Single Photon Emission Computer Tomography (SPECT). The collimator hole angulation for six collimators was measured using a point source and a computer-controlled cylindrical positioning system. In this method, the displacement of the image of a point source was examined as the AQCP was moving point source vertically away from the collimator face. The results of the high-accuracy measurement method of CHA show that the measurement accuracy for absolute angulation errors is better than ±0.024°. The Root Mean Square (RMS) of CHA for LEHR, LEHS and LEUHR collimators of SMV dual heads camera and LEGP, MEGP and HEGP of GE Millennium MG were evaluated to be 0.290°, 0.292°, 0.208°, 0.154°, 0.220° and 0.202°, respectively. It is to be added in this connection that the evaluated RMS of CHA for LEHR collimator with the distance variation from the collimator’s surface ±1 mm has been varied ±0.04 degree. A new method for the center of rotation assessment by AQCP is introduced and the results of this proposed method as compared with the routine QC test and their differences are discussed in detail. We defined and measured a new parameter called Dynamic Mechanical Error (DME) for applying the gantry motion correction.

Cite this paper
Zeinali, H. , Ataee, M. , Ravanbakhsh, H. , Goodarzi, E. , Ghoreishi, S. and Raisali, G. (2014) The Precise Methods for the Measurement of Collimator Hole Angulation and Center of Rotation of SPECT by Adaptive Quality Control Phantom. World Journal of Nuclear Science and Technology, 4, 208-215. doi: 10.4236/wjnst.2014.44026.
References
[1]   Malmin, R.E., Peggy, C.S. and Guth, W.R. (1990) Collimator Angulation Error and Its Effect on SPECT. Journal of Nuclear Medicine, 31, 655-659.

[2]   Busemann-Sokole, E. (1986) Measurement of Collimator Hole Angulation and Camera Head Tilt for Slant and Parallel Hole Collimators Used in SPECT. Journal of Nuclear Medicine, 28, 1592-1598.

[3]   Chang, W, Li, S.Q., Williams, J.J., et al. (1988) New Methods of Examining Gamma Camera Collimators. Journal of Nuclear Medicine, 29, 674-683.

[4]   (1987) Rotating Scintillation Camera SPECT Acceptance Testing and Quality Control. AAPM Report No. 22, American Association of Physicists in Medicine, College Park.

[5]   Quality Control of Nuclear Medicine Instruments (1991) IAEA TECDOC 602. International Atomic Energy Agency, Vienna.

[6]   Eckholt, M. and Bergmann, H. (2000) Angulation Errors in Parallel-Hole and Fan Beam Collimators: Computer Controlled Quality Control and Acceptance Testing Procedure. Journal of Nuclear Medicine, 41, 548-555.

[7]   Takahashi, Y., Murase, K., Higashno, H., et al. (2002) SPECT Imaging with Off-Set Detector System: Comparison of Sampling Angles 2, 4 and 6 Degrees. Annals of Nuclear Medicine, 16, 343-347.
http://dx.doi.org/10.1007/BF02988623

[8]   Hines, H., Kayayan, R., Colsher, J., et al. (1999) Recommendations for Implementing SPECT Instrumentation Quality Control. Nuclear Medicine Section—National Electrical Manufacturers Association (NEMA). European Journal of Nuclear Medicine and Molecular Imaging, 26, 527-532.
http://dx.doi.org/10.1007/s002590050421

[9]   Thomas, G.B. (1969) Calculus and Analytic Geometry. 4th Edition, Addison Wesley, Reading, 340-470.

[10]   National Instruments Corporation. www.NI.com

[11]   Zeinali, H.Z., Ghiassi-Nejad, M. and Mirzai, A. (2007) Design an Adaptive Quality Control Phantom to Optimize QC Test Methods. The Open Medical Imaging Journal, 1, 1-6.
http://dx.doi.org/10.2174/1874347100701010001

[12]   Zeinali, H.Z. and Mirzai, A. (2008) Design an Adaptive Quality Control Phantom to Optimize Integral and Differential Uniformity, Collimator Hole angulation and Center of Rotation of SPECT. The Current Medical Imaging Reviews, 4, 1-8.
http://dx.doi.org/10.2174/157340508784356743

[13]   Kuo, B.C. (1987) Automatic Control Systems. 5th Edition, Prentice-Hall, Upper Saddle River, 290-345.

[14]   Zeinali, H.Z., Ghiassi-Nejad, M. and Mirzai, A. (2008) Design an Adaptive Quality Control Phantom to Optimize Uniformity, Collimator Hole Angulation and Center of Rotation of SPECT. The Journal of Instrumentation, 3, 1-8.
http://dx.doi.org/10.1088/1748-0221/3/02/P02009

 
 
Top