A Study of Hygiene in Swedish Schools and Pre-Schools-Sources of Air Pollution
Abstract: Poor indoor air quality is a large problem in Swedish schools, since the health of occupants may be affected. The building itself is often in focus and other building-related problems may be neglected. The hypothesis of this study is that factors other than the building itself have decisive influence on indoor environment. An assessment of these nonspecific building-related reasons for bad indoor environment has been made in the present work using surveys combined with particle measurements and comfort measurements (air humidity and air temperature). People are experiencing poor indoor air quality, the air is too dry and the temperature is uneven and uncomfortable indoors in the winter. It is important to highlight the problem of indoor environments with high particulate emissions especially in the range from 5.0 microns and larger since they are conveyers of allergens and bacteria, combined with dry air. An interesting observation regarding the ventilation system is that mechanical systems are tending to generate drier indoor air than the natural ventilation system. Results show that it is possible to decrease emissions through eliminating activity-related sources of airborne contaminants and better the comfort indoors with relatively simple measures.
Cite this paper: T. Alsmo and C. Alsmo, "A Study of Hygiene in Swedish Schools and Pre-Schools-Sources of Air Pollution," Journal of Environmental Protection, Vol. 4 No. 12, 2013, pp. 1349-1359. doi: 10.4236/jep.2013.412156.
References

[1]   P. E. Nilsson, “Achieving the Desired Indoor Climate,” Chalmers University of Technology, Gothenburg, 2003.

[2]   K. Asplund, P. Pershagen and M. Svartengren, “Environmental Health Report,” The National Board of Health and Welfare, Stockholm, 2005.

[3]   M. Renstrom, A. C. Egmar and M. Wickman, “A Summary of Knowledge about the Consequences of Cleaning on Allergy and Hyper-sensitivity in Schools and Preschools,” Stockholms Lans Landsting and Swedish National Institute of Public Health, Stockholm, 1996.

[4]   W. W. Nazaroff, “Indoor Particle Dynamics,” Indoor Air, Vol. 14, Suppl. 7, 2004, pp. 175-183.

[5]   The National Board of Health and Welfare, “Message to Boards of Environment and Health Protection, County Administrations and Units for Environmental Medicine of the County Councils, Health Risks with Moisture Problems in Buildings,” 2006.

[6]   Swedish Work Environment Authority, “Plan of Action for Dealing with Sick-Building Problems,” 2008.
http://www.av.se/teman/sjuka_hus/Startintro_sjukahus.aspx

[7]   G. Stridh, “Should We Measure the Chemistry Beneath the Floor Coverage and, If So, How Do We Interpret the Results?” Indoor Climate Orebro, Orebro University Hospital, 2003, pp. 102-108.

[8]   L. Grinbergs, “Mould Resistance of Surfaces in Wet Rooms,” Department of Building Technology, KTH, Royal Institute of Technology, Stockholm, 1992.

[9]   T. Alsmo, “A Study with Surveys and Particle Measurements,” Department of Buildings and Construction, KTH, Royal Institute of Technology, Stockholm, 1994.

[10]   J. Sundell and M. Kjellman, “The Indoor Air We Breathe,” Swedish National Institute of Public Health, Stockholm, 1995.

[11]   Wikipedia, 2008.
http://sv.wikipedia.org/wiki/Sensibilisering

[12]   L. Mansson, “The Invisible Enemy of High-Tech,” TIMAB AB, Malmo, 1992.

[13]   M. Ramtorp, “Clean Technology and Clean Rooms—An Introduction,” BioTeknisk Processdesign AB, Malmo, 1999.

[14]   G. Einberg, “Air Diffusion and Solid Contaminant Behaviour in Room Ventilation—A CFD Based Integrated Approach,” Ph.D. Thesis, Technology and Health, KTH, Royal Institute of Technology, Stockholm, 2005.

[15]   T. Alsmo and S. Holmberg, “Sick Buildings or Not: Indoor Air Quality and Health Problems in Schools,” Vol. 16, No. 6, 2007, pp. 548-555.

[16]   A. Thorn, “The Emergence and Preservation of Sick Building Syndrome, Karolinska Institutet,” Department of Public Health Sciences, Division of Social Medicine, Stockholm, 1999.

[17]   C. Brauer, “The Sick Building Syndrome Revisited,” Department of Occupational Medicine, Copenhagen University Hospital, Glostrup, Denmark, 2005.

[18]   Partiklar i luft, Social & halsovardsministeriet.
http://www.hsy.fi/seututieto/Documents/Ilmanlaatu_esitteet/Partiklar_i_luften.pdf

[19]   TSI Incorporated, 500 Cardigan Road, Shoreview, MN 55126 USA. http://www.tsi.com/en-1033/index.aspx

[20]   B. Ljungqvist, R. Nydahl and B. Reinmüller, “Measurement Technology in Rooms with high demand,” The Royal Institute of Technology, KTH and KABI, Stockholm, 1989.

[21]   The National Board of Housing, Building and Planning, “Law on Technical Requirements for Construction Work,” 2008.

[22]   http://www.testo.com/online/abaxx-?$part=PORTAL.INT.Applications&$event=show-from-content&externalid=opencms:/Products/MeasurementParameters/temperature/
Messgeraete/Datenlogger/testo_175-T2_new/Englisch. product


[23]   http://www.engineeringtoolbox.com/psychrometric-chart-mollier-d_27.html

[24]   A. V. Arundel, E. M. Sterling, J. H. Biggin and T. D. Sterling, “Indirect Health Effects of Relative Humidity in Indoor Environments,” Environmental Health Perspectives, Vol. 65, No. 3, 1986, pp. 351-361.

 
 
Top