Abstract: Mouthguard thickness is affected by the softened state of the sheet during thermoforming. The aim of this study is to establish an effective method for controlling the softened state of the sheet to prevent the mouthguard thickness from decreasing during mouthguard fabrication using a vacuum-forming machine. Mouthguards were thermoformed using an ethylene-vinyl acetate sheet (thickness: 4.0 mm) and a vacuum-forming machine. The working model was trimmed to the anterior height of 25 mm and the posterior height of 20 mm. The following two heating methods were compared: 1) the sheet was formed when it sagged 15 mm below the level of the sheet frame at the top of the post (condition T); and 2) the sheet frame was lowered to and heated at 50 mm below its usual height and the sheet was formed when it sagged 15 mm below the level of the sheet frame (condition L). For each heating method, the vacuum was applied immediately (T0, L0) or 5 s (T5, L5) after the sheet frame was lowered to the forming unit. The sheet surface temperature immediately before the vacuum was applied under each condition was measured. The differences in mouthguard thickness due to forming conditions were analyzed by one-way ANOVA and Bonferroni’s multiple comparison tests. The temperature difference between the center and the posterior depending on the condition decreased in the order T0 > T5 > L0 > L5, and that was 20&deg;C or higher for T0 and T5, and 10&deg;C or less for L0 and L5. At the incisal edge and the cusp, L0 and L5 were significantly thicker than T0. No significant differences were observed between conditions L0 and L5 at any measurement points. For the labial and buccal surfaces, significant differences in thicknesses among all conditions, except L0 and L5, were observed and were in the order T0 < T5 < L0 and L5. This study was suggested that the lowering the sheet frame and heating was more effective than adjusting the vacuum timing for uniform softening of the sheet.
Cite this paper: Takahashi, M. and Bando, Y. (2020) Controlling Softened State of Mouthguard Sheet during Thermoforming to Ensure Thickness. Materials Sciences and Applications, 11, 431-440. doi: 10.4236/msa.2020.117029.
References

[1]   Gawlak, D., Mańka-Malara, K., Mierzwińska-Nastalska, E., Gieleta, R., Kamiński, T. and Luniewska, M. (2017) A Comparison of Impact Force Reduction by Polymer Materials Used for Mouthguard Fabrication. Acta of Bioengineering and Biomechanics, 19, 89-95.

[2]   Tribst, J.P.M., de Oliveira Dal Piva, A.M., Borges, A.L.S. and Bottino, M.A. (2018) Influence of Custom-Made and Stock Mouthguard Thickness on Biomechanical Response to a Simulated Impact. Dental Traumatology, 34, 429-437.
https://doi.org/10.1111/edt.12432

[3]   Westerman, B., Stringfellow, P.M. and Eccleston, J.A. (2002) EVA Mouthguards: How Thick Should They Be? Dental Traumatology, 18, 24-27.
https://doi.org/10.1034/j.1600-9657.2002.180103.x

[4]   Geary, J.L. and Kinirons, M.J. (2008) Post Thermoforming Dimensional Changes of Ethylene Vinyl Acetate Used in Custom-Made Mouthguards for Trauma Prevention: A Pilot Study. Dental Traumatology, 24, 350-355.
https://doi.org/10.1111/j.1600-9657.2007.00550.x

[5]   Takahashi, M., Koide, K. and Mizuhashi, F. (2013) Variation in Mouthguard Thickness due to Different Heating Conditions during Fabrication. Journal of Prosthodontic Research, 57, 179-185.
https://doi.org/10.1016/j.jpor.2013.04.002

[6]   Takahashi, M., Koide, K. and Mizuhashi, F. (2014) Optimal Heating Conditions for Forming a Mouthguard Using a Circle Tray: Effect of Different Conditions on the Thickness and Fit of Formed Mouthguards. Journal of Prosthodontic Research, 58, 171-176.
https://doi.org/10.1016/j.jpor.2014.03.005

[7]   Takahashi, M., Koide, K., Satoh, Y. and Iwasaki, S. (2016) Heating Methods for Reducing Unevenness Softening of Mouthguard Sheets in Vacuum-Pressure Formation. Dental Traumatology, 32, 316-320.
https://doi.org/10.1111/edt.12254

[8]   Takahashi, M. and Koide, K. (2016) Variation in Mouthguard Thickness according to Heating Conditions during Fabrication Part 2: Sheet Shape and Effect of Thermal Shrinkage. Dental Traumatology, 32, 185-191.
https://doi.org/10.1111/edt.12209

[9]   Mizuhashi, F., Koide, K. and Takahashi, M. (2016) Difference in Vacuum-Formed Mouthguard Thickness according to Timing of Vacuum Application. Dental Traumatology, 32, 306-310.
https://doi.org/10.1111/edt.12240

[10]   Takahashi, M., Koide, K., Satoh, Y. and Iwasaki, S. (2016) Shape Change in Mouthguard Sheets during Thermoforming. Dental Traumatology, 32, 379-384.
https://doi.org/10.1111/edt.12261

[11]   Takahashi, M. and Bando, Y. (2018) Effect of the Anteroposterior Position of the Model on Fabricated Mouthguard Thickness: Part 2 Influence of Sheet Thickness and Material. Dental Traumatology, 34, 370-377.
https://doi.org/10.1111/edt.12423

[12]   Takahashi, M. and Bando, Y. (2019) Thermoforming Method to Effectively Maintain Mouthguard Thickness: Effect of Moving the Model Position Just before Vacuum Formation. Dental Traumatology, 35, 121-127.
https://doi.org/10.1111/edt.12447

[13]   Takahashi, M. and Bando, Y. (2020) Thermoforming Technique for Suppressing Reduction in Mouthguard Thickness: Part 2 Effect of Model Height and Model Moving Distance. Dental Traumatology.
https://doi.org/10.1111/edt.12554

[14]   Yamada, J. and Maeda, Y. (2007) Thermoforming Process for Fabricating Oral Appliances: Influence of Heating and Pressure Application Timing on Formability. Journal of Prosthodontics, 16, 452-456.
https://doi.org/10.1111/j.1532-849X.2007.00222.x

 
 
Top