WJNST  Vol.3 No.3 , July 2013
Ion Source Optimisation for Proton Beam Quality of the Van De Graaff Accelerator at iThemba LABS for Ion Beam Analysis
ABSTRACT

The operating principles of the two duoplasmatron ion sources and the PIG source available for the Van de Graaff accelerator have been determined qualitatively, mainly by studying the extensive literature on ion sources. The main characteristics of the three sources have therefore been determined experimentally on an ion source test bench. Important parameters of the sources such as the pressure and temperature in different regions of the sources not measured, because of space limitations. However, in spite of these limitations in quantitative understanding of the sources, sufficient information to continue with the study of the beam transport through the Van de Graaff accelerator and its beamlines could be obtained from these measurements. With regard to beam intensity, lifetime and gas consumption the measurements showed that the hotcathode duoplasmatron is at present by far the most suitable source for the van de Graaff accelerator. The emittance of the ion source was measured with two slits, 90 mm apart, and a Faraday cup in the ion source test bench at an arc voltage of 83 V, an arc current of 1 Amp, a filament voltage of 24 V and an extraction voltage of 5 kV. The measured emittance for 90% of the beam intensity is 48π mm mrad. This figure will be used to calculate the beam transmission through the Van de Graaf accelerator. Different computer programs have been used for these calculations from the ion source through the terminal section, the accelerator and beam line up to the Nuclear Microprobe (NMP) for beam quality.


Cite this paper
M. Eisa, J. Conradie, P. Celliers, J. Delsink, D. Fourie, G. de Villiers, K. Springhorn and C. Pineda-Vargas, "Ion Source Optimisation for Proton Beam Quality of the Van De Graaff Accelerator at iThemba LABS for Ion Beam Analysis," World Journal of Nuclear Science and Technology, Vol. 3 No. 3, 2013, pp. 83-86. doi: 10.4236/wjnst.2013.33014.
References
[1]   J. L. Conradie, M. E. M. Eisa, P. J. Celliers, J. L. G. Delsink, D. T. Fourie, J. G. de Villiers, P. M. Maine, K. A. Springhorn and C. A. Pineda-Vargas, “Recent Optimization of the Beam-Optical Characteristics of the 6 MV van de Graaff Accelerator for High Brightness Beams at the iThemba LABS NMP Facility,” Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 231, No. 1-4, 2005, pp.101-105. doi:10.1016/j.nimb.2005.01.041

[2]   G. W. Grime and F. Watt, “Focusing Protons and Light ions to Micron and Submicron Dimensions,” Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 30, No. 3, 1988, pp. 227-234. doi:10.1016/0168-583X(88)90002-XS.

[3]   Kalbitzer, “Bright Ion Beams for the Nuclear Microprobe,” Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 158, No. 1-3, 1999, pp. 53-60. doi:10.1016/S0168-583X(99)00324-9 D. C. Carey, “Computer Simulation of Charged Particle beams,” Nuclear Instruments and Methods, Vol. 104, No. 1, 1972, pp. 173-178. doi:10.1016/0029-554X(72)90314-X

[4]   D. C. Carey, “High Energy Charged Particle Optics Computer Programs,” Nuclear Instruments and Methods in Physics Research, Vol. 187, No. 1, 1981, pp. 97-102.

[5]   doi:10.1016/0029-554X(81)90475-4

[6]   J. Borburgh, “2-Dimensional Finite Element Calculations on a Septum Magnet with Opera2D,” CERN Note PS/CA/Note 97-27.

[7]   R. Becker and W. B. Herrmannsfeldt, “IGUN—A Program for the Simulation of Positive Ion Extraction Including Magnetic Fields,” Review of Scientific Instruments, Vol. 63, No. 4, 1992, pp. 2756-2761. doi:10.1063/1.1142795

[8]   R. Becker, “INTMAG: A Program for the Calculation of Magnetic Fields by Integration,” Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 42, No. 3, 1993, pp. 303-306.

[9]   R. Becker, “New Features in the Simulation of Ion Extraction with IGUN,” Proceedings of the 6th European Particle Accelerator Conference, Stockholm, June 1998, p. 1165.

[10]   M. L. Mallory and D. H. Crandall, “A Penning Multiply Charged Heavy Ion Source Test Facility,” IEEE Transactions on Nuclear Science, Vol. 23, No. 2, 1976, pp. 1069-1072. doi:10.1109/TNS.1976.4328405

[11]   M. E. M. Eisa, “Optimization of Accelerator Optics and the Application of Nuclear Microscopy to the Biomedical Field,” Ph.D. Dissertation, University of Cape Town, 2005.

[12]   C. A. Pineda-Vargas, M. Topic, T. Ntsoane, W. J. Przybylowicz and M. Harting, “Nuclear Microprobe Analyses of Bioconductive Hydroxyapatite Coatings,” International Conference on Nuclear Microprobe Technology and Applications, Cavtat, 13-17 September 2004.

[13]   C. A. Pineda-Vargas, M. E. Eisa, “Analysis of Human Hair Cross Sections from Two Different Population Groups by Nuclear Microscopy,” Nuclear Instruments and Me- thods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 268, No. 11-12, 2010, pp. 2164-2167. doi:10.1016/j.nimb.2010.02.041

 
 
Top